Automatic heating and pressure processing device
For bubble removal in the LCD/touch panel field and the semiconductor field!
"Resin encapsulation" is an indispensable process for semiconductor assembly. The problem with this process is the bubbles that are generated. The automatic heating and pressurizing device realizes reliable processing with stable temperature distribution in the tank. We have a lineup of functions and sizes that match the sample to be processed.

Automatic Heat and Pressure Processing Equipment ACS Series
Stable temperature distribution. Three types are available to suit the sample being processed. Compatible with N2 gas. →View details

Vacuum to pressure temperature and environment evaluation device BCS-650/G
For various testing and processing of materials and parts in vacuum to pressurized environments. Two types available. →See details

Pressure degassing equipment TBR series
Stable temperature distribution inside the tank. Three types are available, from small to large sizes. →View details
Air bubbles are removed by automatic heating and pressure treatment
This is how air bubbles are removed from OCA film by applying pressure.
Automatic Heat and Pressure Processing Equipment ACS Series



feature
- Stable temperature distribution with a stirring mechanism using a magnetic coupling system
- Lineup of various sizes according to the sample to be processed
- Compatible with N2 gas
- Maximum pressure 0.8 MPaG (1.0 MPaG for option)
specification
| item | ACS-230 | ACS-450 | ACS-650 |
|---|---|---|---|
| Apparatus outline (mm) |
W700 × H1,270 × D785 | W995 × H1,520 × D1,200 | W1,225 × H1,570 × D1,450 |
| Effective inner dimension (mm) |
Φ200×D280 | Φ395×D460 | Φ570 × D565 |
| Weight (kg) | 190 | 500 | 700 |
| power supply | AC100V single phase 15A (100V AC 1Φ15A) |
AC200V single phase 30A (200V AC 1Φ30A) |
AC200V 3-phase 40A (200V AC 3Φ40A) |
| Normal pressure range (gauge pressure) |
Standard: 0.1 to 0.8MPaG Option: 0.1 to 1.0MPaG | ||
| Normal temperature range | Standard: RT+10 to 160°C Option: 180°C or 200°C | ||
| Compressed air supply | 0.9 MPaG (for standard 0.8 MPaG specification) | ||
Vacuum to pressure temperature and environment evaluation device BCS-650/G

feature
- This is an environmental tester that performs various tests on materials, parts, etc. in a vacuum to pressurized environment.
Programmable pressure, temperature and time during testing (16 steps x 64 patterns) - Equipped with a voltage application terminal.
It is possible to connect the power supply and electrical signals of test parts in the pressure vessel to external measuring instruments. - Equipped with two observation windows for camera photography (for lighting + for observation)
It can also be used for deterioration testing by installing a UV lamp. * Compatible models: BCS-650G
specification
| item | BCS-650G | BCS-650 |
|---|---|---|
| External dimensions (mm) | W1225 × H1570 × D1450 | |
| Effective dimension (mm) | φ568×D647 | |
| Volume (L) | 163 | |
| Normal pressure range (gauge pressure) | -90KPaG to 1.0MPaG | -90KPaG to 0.8MPaG |
| Normal temperature range | RT+20~200℃ | RT+20~160℃ |
| power supply | AC200V 3 phase 40A (200V AC 3Φ40A) |
|
| Gas used | Clean compressed air/N2 | |
| Pressure vessel standard | Class 2 pressure vessel | |
| Observation window for camera shooting * | For lighting + for observation (2 pieces) | - |
| Voltage application terminal | For power: 2pin For signal: 12pin | |
* Direct visual observation is not possible for safety reasons. For camera shooting (with mount for camera installation)
Pressure degassing equipment TBR series



feature
- Stable temperature distribution in the tank with a stirring mechanism using a magnetic coupling system
- Lineup from small laboratory type to large size
*The TBR series does not support N2.
specification
| item | TBR-400 | TBR-600 | TBR-901 |
|---|---|---|---|
| Apparatus outline (mm) |
W610 × H1,490 × D840 | W800 × H1,535 × D1,200 | W1,400 × H1,830 × D1,710 |
| Effective dimension (mm) |
Φ395 × D450 | Φ550×D565 | Φ840×D1,040 |
| Weight (kg) | 200 | 300 | 1,000 |
| power supply | AC200V single phase 10A (200V AC 1Φ10A) |
AC200V single phase 15A (200V AC 1Φ15A) |
AC200V single phase 22A (200V AC 1Φ22A) |
| Normal pressure range (gauge pressure) |
0.1 to 0.5MPaG | 0.1 to 0.5MPaG | 0.1 to 0.6MPaG |
| Normal temperature range | RT+10~80℃ | RT+10~70℃ | RT+10~70℃ |
| Compressed air supply | 0.7 to 1.0 MPaG (clean compressed air) | ||
Contact us
Please feel free to contact us for inquiries such as an estimate.